LAMBTON DOORS ArchCat V14 Spt 2019
HARDWARE, FRAME AND ASTRAGAL ACOUSTICAL DOOR STC50
REQUIRED HARDWARE
3 4 " [19mm]
Compression Bulb
29 32 " [23mm]
1 4 " [6mm]
Stabilizer Flange
Available in black only
1 4 " [7mm]
1 4 " [6mm]
1 2 " [13mm]
Self-Adhesive Backing
1 21 32 " [42mm]
S88BL SILICONSEAL
312R PERIMETER GASKETING
1 5 8 " [41mm]
1 4 " [6mm]
sponge neoprene
1 4 " [6mm]
1 2 " [13mm]
434ARL DROP SEAL
5" [127mm] 2005AT THRESHOLD
FIELD MEASUREMENTS
Lambton Doors will not be responsible for field measurements. All STC doors must be undersized 9/16" (14 mm) in total from frame height after finished floor (AFF). Eg. frame 7'0" (2134 mm): Top of door to frame less 1/8" (3 mm) Bottom of door to threshold less 3/16" (5 mm) Total door to frame difference after finished floor (AFF) less 9/16" (14 mm) $FRXVWLFDO GRRU ZLGWK PD\ EH FDOFXODWHG E\ VXEWUDFWLQJ
PP IURP LQVLGH MDPE PHDVXUHPHQW
REQUIRED FRAME AND ASTRAGAL
Concrete filling recommended
1 5 16 " [33mm]
1 2 " [13mm]
S88BL SiliconSeal
2 1 4 " [57mm]
312R Perimeter Gasketing
S88BL Silicon Seal
Active door
Inactive door
STC Door
Gaskets are shown in full size (non-compressed). Lambton Doors recommends the use of 1-1/2" [38 mm] brass screws for installation. T-Astragal not permitted on fire-rated door.
Any standard hollow metal frame. Standard metal frame supplied by others.
FLAT WOOD ASTRAGAL
FRAME
Printed in Canada 2015/12
Made with FlippingBook - professional solution for displaying marketing and sales documents online