LAMBTON DOORS ArchCat V14 Spt 2019

HARDWARE, FRAME AND ASTRAGAL ACOUSTICAL DOOR STC 32-90 min & STC35-90 min

REQUIRED HARDWARE

Compression Bulb

1 4 " [6mm]

29 32 " [23mm]

Stabilizer Flange

Available in black only

1 2 " [13mm]

Self-Adhesive Backing

1 5 8 " [41mm]

1 4 " [6mm]

S88BL SILICONSEAL Œ

1 21 32 " [42mm]

1 4 " [6mm]

1 2 " [13mm]

sponge neoprene

5" [127mm] 2005AT THRESHOLD

434ARL DROP SEAL

FIELD MEASUREMENTS

Lambton Doors will not be responsible for field measurements. All STC doors must be undersized 9/16" (14 mm) in total from frame height after finished floor (AFF). Eg. frame 7'0" (2134 mm): Top of door to frame less 1/8" (3 mm) Bottom of door to threshold less 3/16" (5 mm) Total door to frame difference after finished floor (AFF) less 9/16" (14 mm) $FRXVWLFDO GRRU ZLGWK PD\ EH FDOFXODWHG E\ VXEWUDFWLQJ PP IURP LQVLGH MDPE PHDVXUHPHQW

REQUIRED FRAME AND ASTRAGAL

CONCRETE FILLING RECOMMENDED

S88BL SiliconSeal Œ

1 3 4 " [44mm]

S88BL Silicon Seal Œ

Active door

Inactive door

STC Door

FLAT WOOD ASTRAGAL OR LISTED ASTRAGAL 1-1/2" [38 mm] brass screws for installation. T-Astragal not permitted on fire-rated door. SVR / CVR not shown. Gaskets are shown in full size (non-compressed). Lambton Doors recommends the use of

FRAME Any standard 16 ga. hollow metal frame. Standard metal frame supplied by others.

Printed in Canada 2015/06

Made with FlippingBook - professional solution for displaying marketing and sales documents online