LAMBTON DOORS ArchCat V14 Spt 2019

“ T ” Jamb

TJ-00 Nonrated

TJ-45/60 45 and 60 minute 1 1 8 "

TJ-90 90 minute

TJ-20 20 minute

1 1

1 1

1 1

8 "

8 "

8 "

1

1

4 3 1

4 3 1

4 3

4 3

1 4 "

1 4 "

5 8 "

5 8 "

5 8 "

1

5 8 "

1

1 1

1 1

1 1

1 1

2

8 "

2

8 "

2

8 "

8 "

2

4 3 4

4 3 4

4 3 1

4 3 1

3 2 4 1

1

1

3 2 4 1

1 1

1 1

1 1

1 1

4 "

4 "

4 "

4 "

VARIABLE

VARIABLE

VARIABLE

VARIABLE

5 8 "

5 8 "

5 8 "

5 8 "

1

2

2

2

2

1

1

1

3 2 4

1 1

1 1

1 1

1 1

4 "

4 "

4 "

VARIES

4 "

VARIES

VARIES

VARIES

1 7

1 7

1 7

1 7

8 "

8 "

8 "

8 "

1 4 "

1

1

1

Porte

Mur

Mur

Porte

Porte

Mur

Mur

Porte

1 7

1 7

1 7

1 7

8 "

8 "

8 "

8 "

1 4 "

1

1

1

4

4

1

Wall

Door

Wall

Door

Wall

Door

Wall

Door

1

Bois

1

Bois

Bois

1

1

Bois

Matériau composite ignifuge (MCI) Panneau transversal Placage 2 3 4 1Wood 2 Fire Proof Composite Material (FPCM) 3Crossband 4Veneer Wood Fire Proof Composite Material (FPCM) Crossband Veneer 2 3 4 1

Wood

1

Matériau composite ignifuge (MCI) 1Wood 2 Fire Proof Composite Material (FPCM) 3Crossband 4Veneer Fire Proof Composite Material (FPCM) 2 3 Panneau transversal 2 3

Wood

1

Bois composite (SCL) 1Wood 2Structural Composite Lumber (SCL) 3Crossband 4Veneer Structural Composite Lumber (SCL) Crossband 2 3 Panneau transversal Placage 2 3 4

Bois composite (SCL) 1Wood 2 Structural Composite Lumber (SCL) 3Crossband 4Veneer Wood Structural Composit Lumber (SCL) 2 1 Panneau transversal Placage Crossband 3 2 3 4

Crossband Veneer

Placage 4

4

4

Veneer

4

Veneer

Specifications Wall thickness Minimum 35/8” (92 mm)

Specifications Wall thickness Minimum 33/4” (95 mm)

Specifications Wall thickness Minimum 5” (127 mm) Rated wall as per code requirements Wood casing Standard profiles available. Minimum 5/16” x 15/8” (8mm x 41mm) Conforms to Conforms with Category A and B Positive and Neutral Pressure firedoors.

Specifications Wall thickness Minimum 5” (127 mm) Rated wall as per code requirements Wood casing Standard profiles available. Minimum 5/16” x 15/8” (8mm x 41mm) Conforms to Conforms with Category A and B Positive and Neutral Pressure firedoors.

Rated wall as per code requirements

Wood casing Standard profiles available. Minimum 5/16” x 15/8” (8mm x 41mm) Conforms to Conforms with Positive and Neutral Pressure firedoors.

Wood casing Standard profiles available. Minimum 5/16” x 15/8”.

Conforms to N/A feu de pression neutre et positive

Maximum opening Single: 48” x 108”

Maximum opening Single: 48” x 120”

Maximum opening Single: 48” x 108”

Maximum opening Single: 48” x 96”

(1 219 mm x 2 743 mm)

(1 219 mm x 3 048 mm)

(1 219 mm x 2 743 mm)

(1 219 mm x 2 438 mm)

Pair: 96” x 108”

Pair: 96” x 120”

Paire : 96” x 108”

Pair: 96” x 96”

(2 438 mm x 2 743 mm)

(2 438 mm x 3 048 mm)

(2 438 mm x 2 743 mm)

(2 438 mm x 2 438 mm)

Made with FlippingBook - professional solution for displaying marketing and sales documents online